Criar uma Loja Virtual Grátis


Total de visitas: 28370
IEC 60079-10-Electrical apparatus for explosive

IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas by

IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas



IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas book




IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas ebook
ISBN: 2831863791,
Publisher: IEC
Page: 124
Format: pdf


Table 1 shows the IEC 79-10 zone classification used in Europe and most other parts of the world. IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas. IEC 60079- ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES. ȋ文名称: Electrical apparatus for explosive gas atmospheres--Part 15:Electrical installations in hazardous areas(other than mines) 中标分类: 电工>>低压 采标情况: eqv IEC 60079-14:1996 发布部门: 国家质量技术监督局发布日期: 2000-10- 17 实施日期: 2001-06-01 首发日期: 2000-10-17 复审日期: 2004-10-14 归口单位: 全国防爆电气设备标准化技术委员会主管部门: 中国电器工业协会起草单位: 南阳防爆电气研究所页数: 32页出版社: 中国标准出版社. Zone 0 describes areas in which there is a flammable gas atmosphere present for more than 1000 hours per annum ('continuously'); Zone 1 covers areas where a flammable gas atmosphere is present intermittently for more than 10 hours pa but less . IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification. September 9, 2012 · Download IEC 60079-10-Electrical apparatus for explosive gas atmospheres-Part 10-Classification of hazardous areas pdf · Edit · Delete · Tags · Autopost. IntroductionWhen electrical equipment is used in locations where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust, or ignitible fibers or flyings, the Introduction When electrical These requirements apply to apparatus or parts of apparatus for installation and use in Class I, II, or III, Division 1 hazardous (classified) locations in accordance with the requirements of the National Electrical Code, NFPA 70. Posted by A.K.Hait on 12 July, 2007 - 10:42 pm The reason for sealing between zone-1 and Zone-2 is not only to stop an explosion from propagating between locations but also to prevent the migration of gas or vapour through the conduit. The British Standard BS 5345 Part 2 will become obsolete and replaced by BS/EN/IEC 60079-10. The requirements for equipment to be certified as Ex d or Ex e are set out in various Standards - IEC 60079-1 for Ex d Flameproof equipment, and IEC 60079-7 for Ex e Increased Safety equipment (and documents based on these). Part 14 Installation (and selection) of equipment in hazardous areas. The increase in the use of fieldbus systems in hazardous areas was given a significant boost by the development of an international IEC standard for intrinsically safe (IS) fieldbus systems. IEC 79 classification of hazardous area zones. Table 1 - IEC 79 classification of hazardous area zones. Part 10 Classification of hazardous areas. Electrical apparatus for explosive gas atmospheres – Part 10: Classification of hazardous areas. The factors relevant to the classifications of a hazardous area are the nature of the gases or dust present in the potentially explosive atmosphere.

Other ebooks:
Appreciative Inquiry Handbook: For Leaders of Change pdf download